Top Offtake of Oil

The biggest problem by far with storing large quantitiesmake any screwed joints, capable of allowing air
of oil is the risk of pollution.leakage whatsoever. Even the final fitting to the 10mm
Nothing illustrates this more than the oil pollution causedoil supply pipe is a hydraulic 'push-fit' connection.
by the explosion on the BP oil rig in the Gulf of Mexico.Additional functionality has been included in the design
Whilst our own local domestic oil storage issues mightto make the fitting of this as simple as possible. Things
seem insignificant when compared to this, any pollutionlike a 'floating suction line' that ensure the oil is always
caused can have a devastating effect on the localextracted from the top of the liquid thus avoiding
wild life of an area. This is even more pronounced incontamination from the bottom of the tank and an
places where the contamination can leak into a nearby'in-built oil filter' are integrated into the design as
stream or water course.standard.
This problem has been well known by THESo successful is the Atkinson Tanktop that some tank
ENVIRONMENT AGENCY and OFTEC for a verymanufacturers are already making tanks that do not
long while now.have a bottom outlet, with its potential to cause
OFTEC have attempted to preach good practice in allpollution.
its training courses for installers, whilst THEPossibly the most common question is: "How does the
ENVIRONMENT AGENCY have issued large fines fordevice recognise the difference between the burner
people found to have cause such pollution. In additioncalling for oil and a siphon caused through a broken
to the fines issued by the courts in response topipe?"
charges brought by THE ENVIRONMENT AGENCYWhilst the technology used is not simple, the answer is.
there is also a significant cost for the clean-upBasically the suction pressure from the burner calling
operation that will be required.for oil is much larger than the suction pressure caused
There have been a number of innovations to helpthrough the siphon effect. The anti-siphon device built
reduce the possibility of pollution leaks and it is true tointo the Atkinson Tanktop is clever enough to
say that the numbers of these events are lower thandistinguish between the two and switches off the flow
they were in the pastwhen it recognises that the suction pressure is not
The introduction of de-aeration devices has eliminatedcoming from the pump.
the requirement for having a return pipe taking oil backThe solution is the Atkinson Tanktop
to the tank under pressure.The Atkinson Tanktop has been designed and
The introduction of bunded tanks has helped reducedeveloped for the oil heating industry by Atkinson
pollution events caused through the primary tankEquipment Ltd.
rupturing and leaking oil;The Atkinson Tanktop has arrived, drawing on
The introduction of the Atkinson Overfill Preventionexperience of over 40 years of making products for
Device and the Atkinson Overfill and Bund Alarms hasthe Oil Heating market along with that of burner
help obviate the occurrences of overfill when themanufacturers, tank manufacturers and heating
tanker driver is replenishing the tank contents.engineers. It is a product supported by the Environment
The one glaring contradiction to all of the good workAgencies and OFTEC due to the fact that it
that has been done is the fact that tank manufacturesincorporates an anti-siphon valve to prevent fuel
produce a bunded tank and then go and breach thesiphoning from the tank in the event that the oil line is
bund by putting an outlet pipe between the primarybroken thus avoiding environmental pollution (incurring
tank and the bund wall in order to extract the oil. Thisheavy fines and clean-up costs.
has all the weight of the oil behind it, should there be aDraw oil from your tank safely with the new Atkinson
leak, which could lead to a catastrophic pollution as thisTanktop, Top Offtake System. Leading the way into
is forced out into the environment.the world of Top Offtake, the Atkinson Tanktop is the
The answer seems simple enough. Why not just takeWORLDS FIRST AND ONLY top Offtake device with
the oil out through the top of the tank, withoutall of the features and functions to responsibly draw oil
breaching the bund?from the top of the tank.
Well? Two main reason really:EC Reg. Des. No: 000472493-0001
1) The natural effects of siphon; andThe innovative product has all the components
2) Time equals money.required for drawing fuel oil from the top of the
When we talk about the natural effects of siphon, westorage tank in one unit (no joints to leak oil out or air
need to consider what happens if the feed pipe to thein). It incorporates all of the following into one neat,
burner becomes fractured and broken. Once the oileasy to install, unit:
has started to be lifted out of the tanks and is flowing- Floating Suction head
downwards it does not care whether it is going to the- Silicon suction tube (1.6m)
burner or not. It will just keep on flowing until such time- Non Return Valve
as the supply of oil has run out (i.e. the tank has been- 50 Micron Filter
completely drained out). The answer to this is to fit- Diaphragm Anti-Siphon Valve
what is called an anti-siphon valve. This can detect- Anti-Spill Valve
whether the flow is being caused through the suction- Tank Inlet Fitting 1" BSPM
of the pump or the suction of the siphon effect. In the- Purging/Priming Button
event this detects that it is being caused by a siphon it- Surface gasket
quickly switches of the flow ensuring that not too- Totally Waterproof
much pollution has been caused.With Top Offtake it is imperative that joints are well
When we talk about time equals money, we aremade so with only one joint to make, The Atkinson
talking about the cost of the installer creating a systemTanktop is the answer to an Engineer's dream.
to allow the oil to be extracted from the top off theNow with 10mm push-fit hydraulic connector for simple
tank. This includes making the joints to the anti-siphonfitting (blue connector show in the photograph) inside
valve, top of the tank, etc. This is complicated and canthe restrictive space of the bund - simply push the
lead to many air leaks around the joints, which can10mm oil pipe into place. No screwing and making the
cause the installer lots of grief in identifying andjoint air-tight required whatsoever.
correcting the air leaks in order to get the systemDesigned for the 21st century, where the demand is
functioning. This all adds significant cost to the price offor a system that avoids breaching the bund on an oil
the installation that is ultimately passed on to thestorage tank and thus minimising the risk of
purchaser. Obviously, the householder wants theenvironmental pollution, as supported by the
cheapest possible solution and so an installer thatEnvironment Agencies and OFTEC.
quotes for a system with cheaper conventionalOFTEC has launched a new eco-labeling scheme for
offtake is more likely to get the job than aoil storage tanks.
conscientious installer that wishes to only implement aThe Environmental Risk Assessment (ERA) Scheme
top offtake solution.builds upon successful eco-labeling initiatives in other
Atkinson Equipment Ltd have been a manufacturer toindustries, and rates new oil tanks according to their
the oil industry for many years and have investigatedenvironmental features on a scale from one to 10. The
the problem and created the perfect solution - thelower the number allocated, the lower the risk of an
ATKINSON TANKTOPenvironmental pollution incident.
This has been designed by Atkinson Equipment LtdA tank with an ERA rating of one will be fully bunded,
and is exclusively manufactured in the Atkinsonand will incorporate the latest anti-pollution safeguards.
factory, Westbury, UK.One of these anti-pollution safeguards is Top Offtake
Whilst tackling the primary problem for the installer, thistake of fuel oil from the storage tank instead of
is a product that not only eliminates the possibility of airbottom outlet. The Atkinson Tanktop is well positioned
leaks occurring in the system, it is also extremelyto ensure your tank gets the best ERA rating it can.
simple to fit. All in all, the installer does not have to